Unrecognized Misplaced Intubations

Street Science


 
 

Keith Wesley | | Wednesday, June 27, 2007


Review of: Wirtz DD, Ortiz C, Newman DH: Unrecognized misplacement of endotracheal tubes by ground prehospital providers. Prehospital Emergency Care. 11(2):213-218, 2007

The Science

This was a prospective consecutive case observational study in New York City. The researchers examined the records of all EMS patients who had been intubated in the field or were intubated within 10 minutes of arrival at their emergency department (ED). Confirmation of tube placement was determined by ED physicians who ranged from resident to attending.

During the study period, 192 patients were enrolled. Overall, 132 (69%) were intubated prior to arrival. Of these, 12 (9%) were found to be misplaced, 11 in the esophagus and one in the hypopharyngeal (just above the cords) space. They further identified 20 (15%) where the tube was in the right mainstem bronchus, but this was not considered misplacement. Only one patient with a misplaced tube survived to hospital discharge.

They concluded: The rate of esophageal misplacement of endotracheal tubes in the prehospital environment in our urban setting and the poor clinical course of patients with unrecognized misplacement is consistent with previous reports, suggesting that the benefit of prehospital airway management does not clearly supercede the potential risks.

The Street

We all agree that misplaced endotracheal tubes represent a grave risk to patients. However, does this study provide us any additional information? My first criticism of the study is the use of the ED physician assessment as the Gold Standard for tube placement. In this study, physicians were able to make the determination through a number of tests without actually placing a laryngoscope into the patient. Physicians were allowed to make the determination of misplacement based on lung sounds, gastric sounds, presence of suspected gastric contents in the tube or capnography. The ED physicians were not held to a standardized procedure.

I m not suggesting malice, but I ve seen ET tubes innocently yanked out by docs because they didn t look right when in fact I knew they were properly placed.

What this study failed to tell us was the number of attempts required by EMS for each tube, as well as what tube confirmations were used. It appears from the paper that confirmation of techniques used varied greatly.

Additionally, those patients requiring ED intubation almost always received paralytics upon arrived at the hospital. EMS documented the two primary reasons for not attempting prehospital intubation was the close proximity to the hospital and the need for induction agents.

I commend the authors for attempting to measure the tube misplacement rate in their system. However, the rate of misplacement and the intubation rate overall dropped for a period of time during the study because EMS became aware that there were being monitored. It rose later in the study but did not return to the initial baseline. Word clearly got around that the study was occurring, but the EMS providers were not notified prior to its inception.

The question of whether pre-hospital intubation is safe and, if not, what steps we need to take to make it safe can only be answered if we use a uniform dataset for airway management, such as the one designed by Dr. Henry Wang.

We need to know how many attempts were made, what types of conditions presented, what tube confirmation technique was used, and the results. We need to have verification of placement by ED physician performed using a standardized technique, such as a combination of waveform capnography and direct laryngoscopy.

Although I agree with the authors conclusion, I m not convinced this study proves it. Let s keep trying, though - our patients lives depend on it.




Connect: Have a thought or feedback about this? Add your comment now
Related Topics: Airway and Respiratory, Research

What's Your Take? Comment Now ...

Featured Careers & Jobs in EMS





 

Get JEMS in Your Inbox

 

Fire EMS Blogs


Blogger Browser

Today's Featured Posts

 

EMS Airway Clinic

Simulation-Based Assessment Facilitates Learning & Enhances Clinical Judgment

Simulation is an educational tool that can be used to develop and refine clinical skills of the student in a controlled environment before they progress to becoming practicing clinicians.
More >

Multimedia Thumb

Colorado Medics Ditch Pants for Kilts

“Real men do wear kilts.”
Watch It >


Multimedia Thumb

NYC September 11 Commemoration

Tolling of the bell begins the anniversary ceremony.
Watch It >


Multimedia Thumb

Wrong Fuel Cited in New Mexico Air Ambulance Crash

Plane received jet fuel instead of aviation fuel.
Watch It >


Multimedia Thumb

Wake County EMS PAT

Physical ability test demonstration.
Watch It >


Multimedia Thumb

CO Leak at Illinois School

Girard incident sends over 130 to hospitals.
More >


Multimedia Thumb

Hands On September 2014

Who gets thumbs up this month?
More >


Multimedia Thumb

NYC Sept. 11 Anniversary

View images from the ceremony at Ground Zero.
More >


Multimedia Thumb

VividTrac offered by Vivid Medical - EMS Today 2013

VividTrac, affordable high performance video intubation device.
Watch It >


Multimedia Thumb

The AmbuBus®, Bus Stretcher Conversion Kit - EMS Today 2013

AmbuBus®, Bus Stretcher all-hazards preparedness & response tool
Watch It >


Multimedia Thumb

LMA MAD Nasal™

Needle-free intranasal drug delivery.
Watch It >


Multimedia Thumb

Braun Ambulances' EZ Door Forward

Helps to create a safer ambulance module.
Watch It >


More Product Videos >