Measuring Quality

How machines can help measure our compliance to CPR standards


Michael Levy, MD, FACEP, FAAEM, FACP | From the The Truth about CPR Issue


CPR is one of the fundamental skills that EMS provides, yet most of us probably don't know the quality of the CPR that our system provides. Yes, we may be able to say that we've trained to the latest guidelines and have complete buy-in from our practitioners but can we quantify the "boast" that we provide "great" CPR? In one study of 176 adult patients with out-of-hospital cardiac arrest in Sweden, England and Norway, researchers found ALS CPR provision didn't comply with international guidelines.(1) Chest compressions weren't given 48% of the time without spontaneous circulation, and only a mean of 28% of chest compressions were of adequate depth.

Others have reported similar findings for prehospital and hospital resuscitations. In one study, researchers evaluated CPR with auditory and visual prompts performed on non-randomized victims of cardiac arrest attended by ALS crews.(2) Failure to comply led to an escalation of the prompt, for example from a tone to a voice message. The overall conclusion was that quality of CPR improved when automated feedback was used and that when feedback priority was changed, a parallel increase in quality was noted. There was no improvement in survival to discharge from ventricular fibrillation (V-fib) arrest in the historic group compared to the prompted group, but logistic regression showed an increased short-term survival with increased chest compression.

The authors also noted the unexpected outcome of significant hands off-time despite prompts. This was a different outcome than had been seen in BLS manikin training where compliance was much better, and the authors explained that providers overrode the prompts to accomplish other tasks, presumably IV access and airway placement. Acceptance of the technology was high among the users. It is a reasonable question to ask whether this attention to detail really matters and the answer seems to be "yes."

A study used monitors to measure rate and depth of compressions as well as hands-off time to determine the effect of the quality of CPR on outcome from V-fib arrest of patients.(3) The author concluded that each 5 mm increase in compression depth and each five-second decrease in pre-shock pause leads to an approximate twofold increase in the likelihood of shock success.

Evidence is building that, on the one hand we may not know as much as we need to about how CPR is being delivered in the field, and on the other that the quality of CPR is very important. Tools exist to help us monitor the important aspects of CPR and allow us to provide this feedback to our providers. At a minimum we need to continue to follow this very promising technology and its potential impact on our care.

References

  1. Wik L, Steen PA, Bircher NG. "Quality of bystander cardiopulmonary resuscitation influences outcome after prehospital cardiac arrest." Resuscitation. 28(3):195-203, 1994.
  2. Kramer-Johansen J, Mykelbust J, Wik L et al: "Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: A prospective interventional study." Resuscitation. 71(3):283–292, 2006.
  3. Edelson, DP, Abella BS, Kramer-Johansen J, et al: "Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrest." 



Connect: Have a thought or feedback about this? Add your comment now
Related Topics: Patient Care, Cardiac and Circulation, Operations and Protcols, Patient Management

Michael Levy, MD, FACEP, FAAEM, FACPMichael Levy, MD, FACEP, FAAEM, FACP, is an emergency medicine physician and the medical director of the Anchorage (Alaska) Fire Department.

BROWSE FULL BIO & ARTICLES >

What's Your Take? Comment Now ...

Product Connect

Featured Careers & Jobs in EMS



Subscribe to JEMS & choose your gift!

Get 12 issues of JEMS in print + a free gift.

Award winning content every month, with clinical updates, new product reviews, salary surveys and more. Subscribe today!




EMS Airway Clinic


Fire EMS Blogs


Blogger Browser

Forging a Path

Follow in the footsteps of these inspirational leaders of EMS.
More >


Multimedia Thumb

Keep Yourself Safe

Remember the dangers you face on the streets.
Watch It >


Multimedia Thumb

Washington Waterfall Rescue

13-year old was stuck on ledge above the falls.
Watch It >


Multimedia Thumb

Thank You EMS

Recognizing the EMS community during EMS Week 2012.
Watch It >


Multimedia Thumb

Arkansas Celebrates EMS Week with Parade of Lights

The events also incorporate the introduction of an EMS Hall of Fame.
Watch It >


Multimedia Thumb

Iowa Cave Rescue

One explorer was trapped for over 20 hours.
More >


Multimedia Thumb

Rider Alert Team: Safety Crusade

The Safety Crusade continued this week in honor of Motorcycle Safety Awareness Month.
More >


Multimedia Thumb

Tactical EMS Saved Lives after Giffords Shooting Gallery

Images from our exclusive coverage of the law enforcement officers who provided life-saving care while the Jan. 8, 2011 Safeway shooting scene was unsafe for EMS.
More >


Multimedia Thumb

LMA MAD Nasal™

Needle-free intranasal drug delivery.
Watch It >


Multimedia Thumb

Introducing Flow-Safe II Disposable CPAP

A major leap in product innovation.
Watch It >


Multimedia Thumb

Mercury Medical Air-Q Blocker

Air-Q Blocker is a standard airway device and rescue device.
Watch It >


More Product Videos >