Airways in Cardiac Arrest Patients

 

 
 
 

Keith Wesley, MD, FACEP | | Friday, December 21, 2007


Review of: Abo BN, Hostler D, Wang HE: "Does the type of out-of-hospital airway interfere with other cardiopulmonary resuscitation tasks?" Resuscitation. 72(2), 234-239, 2007.

The Science

Twenty two-paramedic team completed two videotaped advanced cardiac life support (ACLS) scenarios on a human simulator. The simulated patient remained in V-Fib throughout the scenario, and the teams were randomized to either establish an airway using the Combitube or endotracheal intubation. The time to perform three shocks, establish an airway and IV, and deliver the fourth shock were recorded. The time during which no chest compressions were being performed was also recorded. The teams were following the 2000 AHA guidelines.

The study showed that the time required to establish an airway using the Combitube was significantly less than endotracheal intubation (median difference 26.5 seconds). Time without chest compression was less for Combitute than endotracheal intubation (median difference 8.5 seconds). The method did not impact time to establish IV placement, deliver meds or perform the fourth shock.

The authors conclude that the time required to establish an airway and decrease no compression time was better with the Combitube than with endotracheal intubation.

The Street

I ll go ahead and present my bias that we should be moving to the non-visualized airways in cardiac arrest. However, I can't use this study to substantiate this. While I respect the authors for their continued attempts to examine the effect of various airway approaches on cardiac arrest, I believe this study only confuses the issues.

First of all, the teams were using the 2000 AHA guidelines, which didn't accent the critical importance of non-stop chest compression. Secondly, the teams of two medics isn't reflective of the typical pre-hospital cardiac arrest scene where first responders, law enforcement, by-standers and other EMS personnel are available to perform chest compressions during airway management. The authors imply the differences they saw in the simulator would be greater in the field given. I'm not so sure.

Although there is no question that a Combitube can be inserted faster than the ET tube, this study doesn't really answer the question it asks: Does airway management in any form interfere with chest compression? In the discussion section of the article, the authors present data from several papers based on the 2005 guidelines. To use the data gained from these medics performing what at the time was "state of the art" CPR doesn't compare apples to apples.

What are necessary are simulations that are more realistic. Place the simulator in the bathroom with poor lighting. Add a couple of "extra" hands like those I listed before and make sure the crews are well trained in the 2005 guidelines. Then we can see the effect. If was some way to avoid the potential liability issues existed, I'd love to do a study with a camera attached to the medic existed s head, record real-life codes and then make recommendations.

Until then, we must continue to examine the data but do so using scenarios as close to reality as possible.


Connect: Have a thought or feedback about this? Add your comment now
Related Topics: Airway and Respiratory, Research

 
What's Your Take? Comment Now ...

Featured Careers & Jobs in EMS





 

Get JEMS in Your Inbox

 

Fire EMS Blogs


Blogger Browser

Today's Featured Posts

 

EMS Airway Clinic

Simulation-Based Assessment Facilitates Learning & Enhances Clinical Judgment

Simulation is an educational tool that can be used to develop and refine clinical skills of the student in a controlled environment before they progress to becoming practicing clinicians.
More >

Multimedia Thumb

REMSA Programs Helps Reduce Hospital Visits

Community paramedic effort goes into service.
Watch It >


Multimedia Thumb

City Official Challenges San Francisco Fire Chief

Ambulance response times among problems noted by city supervisor.
Watch It >


Multimedia Thumb

Texas Ambulance Crash

Victoria ambulance collides with civilian vehicle.
Watch It >


Multimedia Thumb

Colorado Medics Ditch Pants for Kilts

“Real men do wear kilts.”
Watch It >


Multimedia Thumb

CO Leak at Illinois School

Girard incident sends over 130 to hospitals.
More >


Multimedia Thumb

Hands On September 2014

Who gets thumbs up this month?
More >


Multimedia Thumb

NYC Sept. 11 Anniversary

View images from the ceremony at Ground Zero.
More >


Multimedia Thumb

Field Bridge Xpress ePCR on iPad, Android, Kindle Fire

Sneak peek of customizable run forms & more.
Watch It >


Multimedia Thumb

Braun Ambulances' EZ Door Forward

Helps to create a safer ambulance module.
Watch It >


Multimedia Thumb

VividTrac offered by Vivid Medical - EMS Today 2013

VividTrac, affordable high performance video intubation device.
Watch It >


More Product Videos >